1
Hi, Guest!

  LOKASI :  Wonogiri

  AKTIVITAS :  04/09/2019

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !
Industrial Valve Flow Switch

Hach Solitax 6940100

Update Terakhir
:
22 / 03 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
TEGALREJO INTERNATIONAL ONLINE TECHNOLOGY ( Tio-Tech ) Adalah Perusahaan Pribumi yang berbekalPendidikandanPengalamandanmerupakansalahsatu Group Perusahaan Besar di Jakarta yang bekerjasamadengan Perusahaan LuardanDalamNegeri yang bergerakdidalam Engineering dan Trading.

Detail Hach Solitax 6940100

Overview Measure turbidity and suspended solids - with no color interference. Hach' s SOLITAX sc Suspended Solids and Turbidity Analyzer makes it easy to measure sludge concentration and turbidity values in wastewater, drinking water, and manufacturing processes. Whether you need to assess activated sludge and the entire biological cleaning stage, analyze the purified discharge of wastewater treatment, or monitor sludge at various stages of concentration, the SOLITAX sc Suspended Solids and Turbidity Analyzer gives you accurate and continuous measurements - completely independent of color. Hach' s SOLITAX sc Suspended Solids and Turbidity Analyzer automatically compensates for changes in activated sludge color caused by variations in through-flow volume, annual climatic fluctuations, or other unexpected events. Unlike conventional systems which require you to continually compensate for color variation, the proven " measured value constancy" and " measured value reproducibility" of the SOLITAX sc Suspended Solids and Turbidity Analyzer allows you to improve overall plant efficiency with faster, more reliable analysis and lower costs for operation and maintenance. Features / Benefits * Accurate, Color-independent Measurement * Self-cleaning Device Prevents Erroneous Values * Excellent Correlation to Laboratory Analysis * Fully Serviceable Sensors extends the life of the sensor * Easy One-point Calibration * Versatile Mounting Styles for immersion in open tanks or insertion in pressurized pipes Specifications RANGE Sensors for immersion in open tanks Model t-line sc sensor Turbidity only: 0.001 to 4000 NTU Model ts-line sc sensor Turbidity: 0.001 to 4000 NTU Suspended Solids: 0.001 mg/ L to 50 g/ L Model hs-line sc sensor Turbidity: 0.001 to 4000 NTU Suspended Solids: 0.001 mg/ L to 500 g/ L Sensors for immersion in pipes Model inline sc sensors Turbidity: 0.001 to 4000 NTU Suspended Solids: 0.001 mg/ L to 50 g/ L Model highline sc sensors Turbidity: 0.001 to 4000 NTU Suspended Solids: 0.001 mg/ L to 500 g/ L Units of Measure Turbidity User selectable - NTU, FNU, or TE/ F Suspended Solids User selectable - g/ L, mg/ L, ppm, or % solids Accuracy ( Defined according to ISO/ WD 13530) Turbidity Less than 1% of reading or ± 0.001 NTU, whichever is greater Suspended Solids Less than 5% of reading ( depends on homogeneity of municipal activated sludge) Repeatability ( Defined according to ISO/ WD 13530) Turbidity Less than 1% of reading Suspended Solids Less than 3% of reading ( depends on the homogeneity of municipal activated sludge) Detection Limit Turbidity 0.001 NTU Suspended Solids 0.001 mg/ L Response Time Initial response in 1 second Signal Average Time User selectable ranging from 10 to 300 seconds Calibration Turbidity Formazin or StablCal® Standard Suspended Solids Based on gravimetric TSS analysis with a correction factor procedure Certifications CE certified to EN 61326-1, EN 61326/ A1, EN 61326/ A2, EN 61010-1 MOUNTING For insertion in pipes: Through sidewall of a pipeline using a ball valve; minimum pipe size 100 mm ( 4 in.) in carbon or stainless steel For immersion in open tanks: Fixed to rim of tank Flow Velocity 3 m/ s ( 9.8 ft/ s) maximum Operating Temperature 0 to 40 ° C ( 32 to 104 ° F) Sample Temperature 0 to 40 ° C ( 32 to 104 ° F) DIMENSIONS Insertion sensor: 60 X 315 mm ( 2.4 x 12.4 in.) Ball valve from flange: 185 x 625 mm ( 7.3 x 24.6 in.) Immersion sensor: 60 x 200 mm ( 2.4 x 7.9 in.) WEIGHT Insertion, Stainless Steel: 2.4 kg ( 5.3 lb) Immersion, Stainless Steel: 1.38 kg ( 3.0 lb) Immersion, PVC: 0.52 kg ( 1.2 lb) Cable Length 10 m ( 33 ft.) standard. Optional extension cables available in 7.6 m ( 25 ft.) , 15.2 m ( 50 ft.) , 30.5 m ( 100 ft.) . Maximum total length: 100 m ( 328 ft.) Specifications subject to change.
Tampilkan Lebih Banyak
tegalrejo international online technology
Bogor Office: Ruko Taman Victoria Blok F No. 1 Jl. Taman Victoria, Sentul City, Bogor 16810 Telp: 02182749551/02182749561 Solo Office: Jl. Adi Sumarmo Km. 6,5, Gedongan, Colomadu, Karanganyar, Jateng 57173 Telp : (0271) 7464-538, Fax : (0271) 7464-538, Wonogiri
Indonesia 16810
Wonogiri
04 / 09 / 2019
Hubungi Kami

Detail Hach Solitax 6940100

Overview Measure turbidity and suspended solids - with no color interference. Hach' s SOLITAX sc Suspended Solids and Turbidity Analyzer makes it easy to measure sludge concentration and turbidity values in wastewater, drinking water, and manufacturing processes. Whether you need to assess activated sludge and the entire biological cleaning stage, analyze the purified discharge of wastewater treatment, or monitor sludge at various stages of concentration, the SOLITAX sc Suspended Solids and Turbidity Analyzer gives you accurate and continuous measurements - completely independent of color. Hach' s SOLITAX sc Suspended Solids and Turbidity Analyzer automatically compensates for changes in activated sludge color caused by variations in through-flow volume, annual climatic fluctuations, or other unexpected events. Unlike conventional systems which require you to continually compensate for color variation, the proven " measured value constancy" and " measured value reproducibility" of the SOLITAX sc Suspended Solids and Turbidity Analyzer allows you to improve overall plant efficiency with faster, more reliable analysis and lower costs for operation and maintenance. Features / Benefits * Accurate, Color-independent Measurement * Self-cleaning Device Prevents Erroneous Values * Excellent Correlation to Laboratory Analysis * Fully Serviceable Sensors extends the life of the sensor * Easy One-point Calibration * Versatile Mounting Styles for immersion in open tanks or insertion in pressurized pipes Specifications RANGE Sensors for immersion in open tanks Model t-line sc sensor Turbidity only: 0.001 to 4000 NTU Model ts-line sc sensor Turbidity: 0.001 to 4000 NTU Suspended Solids: 0.001 mg/ L to 50 g/ L Model hs-line sc sensor Turbidity: 0.001 to 4000 NTU Suspended Solids: 0.001 mg/ L to 500 g/ L Sensors for immersion in pipes Model inline sc sensors Turbidity: 0.001 to 4000 NTU Suspended Solids: 0.001 mg/ L to 50 g/ L Model highline sc sensors Turbidity: 0.001 to 4000 NTU Suspended Solids: 0.001 mg/ L to 500 g/ L Units of Measure Turbidity User selectable - NTU, FNU, or TE/ F Suspended Solids User selectable - g/ L, mg/ L, ppm, or % solids Accuracy ( Defined according to ISO/ WD 13530) Turbidity Less than 1% of reading or ± 0.001 NTU, whichever is greater Suspended Solids Less than 5% of reading ( depends on homogeneity of municipal activated sludge) Repeatability ( Defined according to ISO/ WD 13530) Turbidity Less than 1% of reading Suspended Solids Less than 3% of reading ( depends on the homogeneity of municipal activated sludge) Detection Limit Turbidity 0.001 NTU Suspended Solids 0.001 mg/ L Response Time Initial response in 1 second Signal Average Time User selectable ranging from 10 to 300 seconds Calibration Turbidity Formazin or StablCal® Standard Suspended Solids Based on gravimetric TSS analysis with a correction factor procedure Certifications CE certified to EN 61326-1, EN 61326/ A1, EN 61326/ A2, EN 61010-1 MOUNTING For insertion in pipes: Through sidewall of a pipeline using a ball valve; minimum pipe size 100 mm ( 4 in.) in carbon or stainless steel For immersion in open tanks: Fixed to rim of tank Flow Velocity 3 m/ s ( 9.8 ft/ s) maximum Operating Temperature 0 to 40 ° C ( 32 to 104 ° F) Sample Temperature 0 to 40 ° C ( 32 to 104 ° F) DIMENSIONS Insertion sensor: 60 X 315 mm ( 2.4 x 12.4 in.) Ball valve from flange: 185 x 625 mm ( 7.3 x 24.6 in.) Immersion sensor: 60 x 200 mm ( 2.4 x 7.9 in.) WEIGHT Insertion, Stainless Steel: 2.4 kg ( 5.3 lb) Immersion, Stainless Steel: 1.38 kg ( 3.0 lb) Immersion, PVC: 0.52 kg ( 1.2 lb) Cable Length 10 m ( 33 ft.) standard. Optional extension cables available in 7.6 m ( 25 ft.) , 15.2 m ( 50 ft.) , 30.5 m ( 100 ft.) . Maximum total length: 100 m ( 328 ft.) Specifications subject to change.
Tampilkan Lebih Banyak